Validity and Reliability of Farra Eye Model as a Surgical Simulator for Capsulorhexis Training Oral Presentation - Observational Study - Resident

HANIFAH RAHMANI NURSANTI (1) , Julie Dewi Barliana (2) , Syska Widyawati (3) , Faraby Martha (4) , Levina Chandra Khoe (5)
(1) , Indonesia
(2) , Indonesia
(3) , Indonesia
(4) , Indonesia
(5) , Indonesia

Abstract

Abstract


Introduction & Objectives : Various simulation models are available for cataract surgery training. Farra Eye Model, a new cataract surgery simulator, was developed to provide the resident with more affordable options. This study aims to determine the validity and reliability of the Farra Eye Model as a surgical simulator for capsulorhexis training.


Methods : A cross-sectional pilot study was performed among ophthalmology residents and consultants to assess face, content, and construct validity of a new surgical simulator. Subjects were divided into novice, intermediate, and expert groups according to their level of expertise. Face and content validity was assessed using a validated questionnaire with a 5-point Likert scale response. Construct validity was done by comparing capsulorhexis performance between the three groups. Two raters assessed performance using capsulorhexis indices in ICO-OSCAR: Phaco assessment tool, number of forceps grabs, and duration of capsulorhexis.


Results : A total of 33 subjects were recruited and divided equally into three groups. The overall face validity score was favorable (3.67 ± 0.67). However, the capsule elasticity was rated poor (2.73 ± 1.1) among the intermediate group. The content validity was favorable regarding the overall score (4.15
± 0.58) and each assessment component. In the construct validity test, intermediate and expert groups showed better capsulorhexis performance than the novice group on all parameters (p<0.001), with good inter-rater reliability (ICC>0.7).


Conclusion : Farra Eye Model has a good face and content validity for capsulorhexis training and is able to differentiate the novice group from intermediate and expert groups. However, it remains a challenge to replicate human lens capsule elasticity.

Full text article

Generated from XML file

References

(-)

Authors

HANIFAH RAHMANI NURSANTI
Julie Dewi Barliana
Syska Widyawati
Faraby Martha
Levina Chandra Khoe
HANIFAH RAHMANI NURSANTI, Julie Dewi Barliana, Syska Widyawati, Faraby Martha, & Levina Chandra Khoe. (2024). Validity and Reliability of Farra Eye Model as a Surgical Simulator for Capsulorhexis Training: Oral Presentation - Observational Study - Resident. Ophthalmologica Indonesiana, 49(S2). https://doi.org/10.35749/w12r3545

Article Details

How to Cite

HANIFAH RAHMANI NURSANTI, Julie Dewi Barliana, Syska Widyawati, Faraby Martha, & Levina Chandra Khoe. (2024). Validity and Reliability of Farra Eye Model as a Surgical Simulator for Capsulorhexis Training: Oral Presentation - Observational Study - Resident. Ophthalmologica Indonesiana, 49(S2). https://doi.org/10.35749/w12r3545

Udayana University Eye Care Program at T.C.Hillers Hospital

Andy William, Komang Putra Tridiyoga, Ni Made Ari Suryathi, Putu Budhiastra, Anak Agung Mas...
Abstract View : 0

Udayana University Eye Care Program at T.C.Hillers Hospital

Andy William, Komang Putra Tridiyoga, Ni Made Ari Suryathi, Putu Budhiastra, Anak Agung Mas...
Abstract View : 0